Método Verde e Rápido na Pesquisa da Presença de PG e PABA em Cremes Hidratantes
publicado em 19/04/2020
G Giraldi Shimamoto, J Terra, MI Maretti Silveira Bueno
Instituto de Química, Universidade Estadual de Campinas - Unicamp, Campinas SP, Brasil
As ferramentas quimiométricas de Análise de Componentes Principais, Mínimos Quadrados Parciais para Análise Discriminante e K-ésimo vizinho mais próximo foram aplicadas a espectros de fluorescência de raios X de cremes hidratantes para identificar simultaneamente a presença de propilenoglicol e parabenos, o que produziu classificação de amostras externas com 100% de acerto.
Principal Component Analysis, Partial Least Squares Discriminant Analysis and K-Nearest Neighbors methods were applied to X-ray fluorescence spectra of moisturizers in order to identify simultaneously propylene glycol and parabens, that produced external sample classifications with accuracies of 100%
Se aplicaron las herramientas quimiométricas de Análisis de Componentes Principales, Mínimos Cuadrados Parciales para Análisis Discriminante y K-Vecinos más Cercanos en los espectros de fluorescencia de rayos X de cremas hidratantes para identificar simultáneamente la presencia de propilenglicol y parabenos, que produjo clasificación de muestras externas con 100% de acierto.
Parte Experimental
Resultados e Discussão
Conclusão
Os cremes hidratantes são muito utilizados como cosméticos, principalmente para o tratamento da pele seca que, sem esses cremes, pode tem descamações, fissuras, tensão e vermelhidão, promovendo, inclusive, sangramento 1. Paralelamente, cremes podem ser associa dos a princípios ativos específicos, com ação medicamentosa para prevenir, curar ou tratar patologias, principalmente dermatológicas.
Apesar dos diversos aspectos benéficos, cabe destacar que os cremes hidratantes podem conter em sua formulação substâncias que podem se tornar prejudiciais à saúde, dependendo da concentração, como, por exemplo: propilenoglicol e parabenos. Em contato com a pele, o propilenoglicol pode causar irritações e alergias cutâneas2-4 e os parabenos podem até
Para visualizar o restante do artigo faça seu login ou então se cadastre gratuitamente e acesse todo o conteúdo disponível.
1. ALK Milan, D Milão, AA Souto, TWF Corte. Estudo da hidratação da pele por emulsões cosméticas para xerose e sua estabilidade por reologia. Rev Bras Cienc Farm 43(4):649-657, 2007
2. Y Horiguchi, T Honda, S Fujii, S Matsushima, Y Osaki. A case of allergic contact dermatitis from propylene glycol in an ultrasonic gel, sensitized at a leakage skin injury due to transcatheter arterial chemoembolization for hepatocellular carcinoma. Int J Dermatol 44(8):681-683, 2005
3. JO Funk, HI Maibach. Propylene glycol dermatitis: re-evaluation of an old problem. Contact Dermatitis 31(4):236-241, 1994
4. CS De Galdeano, A Aguirre, JA Ratón, R Zabala, N Landa, JL Diaz-Perez. Contact dermatitis from a moisturizing cream. Contact Dermatitis 30(1):50-51, 1994
5. L Barr, G Metaxas, CAJ Harbach, LA Savoyc, PDJ Darbred. Measurement of paraben concentrations in human breast tissue at serial locations across the breast from axilla to sternum. J Appl Toxicol 32(3):219-232, 2012
6. AA Fisher. Paraben dermatitis due to a new medicated bandage: the “paraben paradox”. Contact Dermatitis 5(4):273-274, 1979
7. EM Warshaw, NC Botto, HI Maibach, JFJR Fowler, RL Rietschel, KA Zug, DV Belsito, JS Taylor, VA Deleo, MD Pratt, D Sasseville, FJ Storrs, JGJR Marks, CG Mathias. Positive patch-test reactions to propylene glycol: a retrospective cross-sectional analysis from the North American Contact Dermatitis Group, 1996 to 2006. Dermatitis 20(1):14-20, 2009
8. E Blanco, MDC Casais, MDC Mejuto, R Cela. Combination of off-line solid-phase extraction and on-column sample stacking for sensitive determination of parabens and p-hydroxybenzoic acid in waters by non-aqueous capillary electrophoresis. Anal Chim Acta 647(1):104-111, 2009
9. ES Gil, CH Andrade, NL Barbosa, RC Braga, SHP Serrano. Cyclic voltammetry and computational chemistry studies on the evaluation of the redox behavior of parabens and other analogues. J Braz Chem Soc 23(3):565-572, 2012
10. PD Darbre, A Aljarrah, WR Miller, NG Coldham, MJ Sauer, GS Pope. Concentrations of parabens in human breast tumours, J Appl Toxicol 24(1):5-13, 2004
11. CJ Park, WH Nah, JE Lee, YS Oh, MC Gye. Butyl paraben-induced changes in DNA methylation in rat epididymal spermatozoa. Int J Androl 44(1):187-193, 2012
12. M Kawaguchi, K Irie, K Morohoshi, G Watanabe, K Taya, M Morita, Y Kondo, H Imai, T Himi. Maternal isobutyl-paraben exposure alters anxiety and passive avoidance test performance in adult male rats. Neuroscience Research 65(2):136-140, 2009
13. M Kawaguchi, K Morohoshi, H Imai, M Morita, N Kato, T Himi. Maternal Exposure to Isobutyl-Paraben Impairs Social Recognition in Adult Female Rats. Exp Anim 59(5):631-635, 2010
14. Resolução RDC nº 162 da Agência Nacional de Vigilância Sanitária. Disponível em http://portal.anvisa.gov.br. Acesso em: 15 ago 2014
15. G Shanmugam, BR Ramaswamy, V Radhakrishnan. H Tao. GC–MS method for the determination of paraben preservatives in the human breast cancerous tissue. Microchem J 96(2):391-396, 2010
16. T Zhou, HY Zhang, GL Duan. Simultaneous determination of diethylene glycol and propylene glycol in pharmaceutical products by HPLC after precolumn derivatization with p-toluenesulfonyl isocyanate. J Sep Sci 30(16):2620-2627, 2007
17. D Ivanovic, M Medenica, E Nivaudguernet, M Guernet. Effect of pH on the retention behavior of some preservatives-antioxidants in reversed-phase high-performance liquid-chromatography. Chromatographia 40(11):652-656, 1995
18. A Geahchan, M Pierson, P Chambon. Gas-chromatographic determination of preservatives in rennet. Chromatography 176(1):123-125, 1979
19. DA Skoog, FJ Holler, TA Nilman. Princípios da Análise Instrumental, 5ª. edição, Bookman, Porto Alegre, 2002
20. M West, AT Ellis, PJ Potts, C Streli, C Vanhoof, D Wegrzynek, P Wobrauschek. Atomic spectrometry update - X-ray fluorescence spectrometry. J Anal At Spectrom 27(10):1603-1644, 2012
21. GG Shimamoto, B Kazitoris, LFR De Lima, ND De Abreu, VT Salvador, MIMS Bueno, EVR De Castro, EAS Filho, W Romão. Quantificação de antimônio em garrafas de politereftalato de etileno (PET) brasileiras por fluorescência de raios-X e avaliação quimiométrica para verifi car a presença de PET reciclado através do teor de ferro. Quím Nova 34(8):1389-1393, 2011
22. J Terra, AM Antunes, MA Prado, MIMS Bueno. Energy value determinations of industrialized foods: the potential of using X-ray spectroscopy and partial least squares. X-Ray Spectrom 39(3):167- 175, 2010
23. K Tsuji, J Injuk, V Grieken. X-Ray Spectrometry Recent Techonological Advances, 1a. edição, Wiley, Chichester, 2004
24. Moisturizers – Cosmetics Info: The Science & Safety Behind Your Favorite Products. Disponível em: http://www.cosmeticsinfo.org.Acesso em: 15 ago 2014
25. M Barker, W Rayens. Partial least squares for discrimination. J Chemom 17:166, 2003
Deixar comentário
Para comentar é preciso fazer login no sistema.